CONTAINER TECHNICAL SPECIFICATIONS
PRODUCT DIMENSION Mention dimensions of the containers in the contract, All dimensions may vary aprox. ± 50mm
METAL PARTS 1311 Erdemir Galvanized
CEMENT BOARD TSE 634-2
TECHNICAL DATA
EARTHQUAKE CONDITIONS 1st Degree
CLIMATE CONDITIONS 3rd Climate Zone
SNOW LOAD 80 Kg/m²
WIND SPEED 80 Km/h The product must be fixed to the ground.
POLYSTYRENE FOAM (EPS) TS EN 13163
TRANSMISSION COEFFICIENT OF EXTERNAL WALL 0,46 W/m²K
ROOF TRASMISSION COEFFICIENT 0,26 W/m²K
FLOOR HEAT TRANSFER COEFFICIENT 1,24 W/m²K
CHASSIS LOADING CAPACITY 200 Kg/m²
FLOOR
SYSTEM Specially Shaped profile and bolted joint construction in use. The product must be placed on a flat and stable surface.
FLOOR COATING 2.5 mm thick PVC vinyl are used on 14 mm thick cement board.
WALLS
SYSTEM Specially shaped sandwich panel with EPS insulation.
OUTER SURFACE COVERING Ral 9002 electrostatic painted steel sheet.
INNER SURFACE COVERING Ral 9002 electrostatic painted steel sheet.
WALL INSULATION Produced with 50 mm thick 14 kg/m³ polystyrene foam (EPS) B2 fire class fire resistant, full thermal insulation, healthy and safety materials.
ROOF
ROOF SYSTEM Special shaped clamped (grooved seam) EPS sandwich panels. Rain water will be drained through special clamping system.
ROOF INSULATION Produced with 120 mm thick 14 kg/m³ polystyrene foam (EPS) B2 fire class fire resistant, full thermal insulation, healthy and safe materials.
OUTER SURFACE COATING Ral 9002 electrostatic painted steel sheet.
INNER SURFACE COVERING Ral 9002 electrostatic painted steel sheet.
DOORS
EXTERNAL DOOR Made of Metal door frame and 40 mm sandwich panel that is additionaly reinforced with metal and leakproof gasket and PVC joints.
INTERNAL DOOR MDF door with electrostatic painted galvanized metal frame (1980X755mm)
WINDOWS
WINDOW 875x1135 mm PVC window. Windows are single wing and opens 90 degree.
SILL PVC is used on the window sill of the inside edge.
GLASS Double glazing glass.
PAINTING
EXTERIOR AND INTERIOR Ral 9002 electrostatic painted steel sheet.
METAL PARTS Ral 1019 electrostatic painted steel sheet.
ELECTRIC INSTALLATIONS
SYSTEM On the plaster
CABLE For plugs 3x2,5 and for lighting 2x1,5 NYM TSE certified cables in use.
LIGHTING Materials with TSE certified materials.
PLUGS AND SWITCHES Located in every room.
SANITARY INSTALLATIONS
SYSTEM On the plaster
CLOSET PAN TSE certified ceramic in used.
CLOSET TSE certified ceramic in used.
SHOWER TRAY Acrylic based TSE certified products are in used. (Shower Trays are not in use in our WC-Shower Container products.)
SINK Made of ABS and TSE certified materials in use.
FRESH WATER PIPING PPRC featured material in use with TSE certification.
WASTE WATER PIPING PVC featured materials in use with TSE certification.
ACCESORIES Mirror, toilet paper holder and soap holders etc are TSE certified materials.
WC-SHOWER
VENTILATION Shower curtains are used for shower units. 210mm x 250mm vent is used for shower and WC units. For the hallways 2 units of 600mm x 400mm transoms are used and placed on both sidewalls .
FLOOR AND WALL COVERINGS The shower floor is covered completly with PVC vinyl. Walls are covered with PVC vinyl up to 1300mm height ( except partition walls). In Wc units, walls and floor are covered with PVC vinyl up to minimum 300 mm. The shower floor is covered completly with PVC vinyl. Walls are covered with PVC vinyl up to 1300mm height ( except partition walls). In Wc units, walls and floor are covered with PVC vinyl up to minimum 300 mm.
DOOR For Wc 900mm doors are used, which open outwards.
LIGHTING A Moisture-proof luminaire 2x18 sized fixture is used.
DELIVERY
Lifting is made with specially designed brackets and columns.
Karmod Prefabricated Building Technologies has the right to make modifications in the Technical Specifications.